Home    Company Information    What's New    Contact Us   

 
QUIKLOOK II Software
valve testing sensors / systems / software


Download the brochure

Revision history
Common platform design and operation

• Teledyne’s QUIKLOOK II, QL II+, and SENTRY platforms all use the same software

• Start and stop triggers enable unattended operation of any of the three systems

Data acquisition

• Screens and keyboard shortcuts virtually identical to QUIKLOOK for DOS

• Data acquisition is integrated with the Windowsbased analysis software

• Monitor screen displays all input channel values in both volts and engineering units

• Monitor screen displays single-channel bar or line graph or pretension level / target range window

• Data acquisition rates up to 10,000 samples per second

Plots

• No limit to the number of traces that can be plotted in a pane; up to 6 panes may be displayed on the screen at once

• Panes are independently resizeable

• Plot annotations available: data point values, text and footnotes

• Markers shown on trending plots: none, all, or currently-selected test only

• XY plotting

• Plot preference controls: color / background, maximum number of points, default title, legend style and channel unit groups

• Customized plots can be saved or exported in .pdf format

• FFT Y-axis scaling may be logarithmic or linear, and more resolution choices are available

• A motor power channel can be displayed without having been previously calculated using Plot Setup

Test data

• Channel names and units may now be longer, up to 30 characters

• An additional unlimited comment field has been added

• List Edits displays all changes made to the test data

• The Test Data form now includes the Channel, Marker, QA, and Times & Loads Data forms via tabs for simpler operation

• The Channel Data tabbed form now includes channel dependencies and calculation channel equation information

Analysis

• Average running loads, lights and stroke times

• Analysis of motor power phasing with sensor selfcorrection feature

• Dependent (calculated) channels are recalculated if the channel on which they are based is changed

• Calculated channels numbered 17-50 are saved with the other test data

• Calculated channels numbered 51-500 are temporary

• All traces on the screen can be zeroed at once

• Sensor calibration curves (linear, 2nd order, or 3rd order) are generated from a calibration test • A linear, 2nd order, or 3rd order calibration may be applied to acquired data

Standard and custom reports

• Several standard reports are now available

• Any client report can be replicated for use within QUIKLOOK II

Self verification

• QUIKLOOK II automatically performs a self-check verification every time it is started

   