Teledyne Instruments - Test Services (TTS) offers a unique Automotive Torque testing tool, the RT100 Torque Sensing System, designed for long term in-vehicle or dynamometer testing. No outboard wiring or slip rings are required.
The RT100 is entirely weatherproof making it an excellent choice for fleet testing. The RT100 uses non-contact, data transfer technology providing the user with a clean and responsive signal. Power is supplied to the rotating collar inductively eliminating the need for batteries.
The RT100 is truly a “hands off” torque measurement system, as once installed, it is invisible to the user. TTS offers this exciting product as a turnkey installation onto the customer’s driveshaft.
Features:
- Operates in rain, snow and mud
- Designed for unattended testing
- Shunt calibration from inside the vehicle
- Analog output with 1 kHz frequency response
- User selectable scaling
- Collar projects 0.62 inches from shaft diameter, 3.9 inches long
- Custom form factors available
- Turnkey installation available with 0.5% accuracy NIST traceable
- Temperature compensated -15 to +75°C, -40 to +120 available
- No batteries or slip rings
- Non-critical antenna placement (±0.75 inches)
- Light weight collar does not present balance problems
- Racing and dynamometer units available
- Two channel versions available for measuring thrust, strain or temperature
Applications:
- Transmission development
- Engine development
- Powertrain torque monitoring
- Traction control
- Racing vehicles
- Fleet testing
- Customer use testing
Specifications:
| RT100 Shaft Electronics (Rotor & Stator) |
| Torque capacity: |
Dependent on shaft size, typically ±3500 ft-lbs |
| Calibration range: |
0 to 6000 ft-lbs (8100 Nm) |
| Operating temperature range: |
-15 to +75°C (-40 to +120°C available) |
| Physical size: |
0.62 inches radial projection typical, 3.9 to 5.5 inches long based on required form factor |
| Environmental concerns: |
Completely weatherproof injection molded collar |
| Maximum speed: |
8000 RPM typical (shaft diameter dependent) |
| RT100 Stationary Electronics (Receiver) |
| Combined accuracy: |
< .5% FS |
| Calibration: |
Remote shunt calibration (receiver momentary toggle) |
| System frequency response: |
1000 or 100 Hz (-3dB), user selectable |
| Output signal: |
0 ±2 to ±10V user selectable and scaleable |
| Input power requirements: |
8-32 VDC, 1.6 amp @ 12V |
| Operating temperature range: |
0 to 70°C (32 - 158°F) |
| Physical size (LxWxH): |
9.0" x 4.1" x 3.1" |
|
|
|